High-pressure fog cannon through the built-in high-pressure pump, the water pressure will be raised to hundreds of megapascals, and then through the special nozzle will be fogged into 10-50 micron tiny particles. This high-pressure effect not only makes the water mist particles more fine, increasing its contact area with pollutants in the air, but also improves the permeability of the water mist, so that it can better adsorb and settle dust and harmful gases. So how to adjust the pressure of high-pressure fog cannon? The following Zheng Tong fog cannon small will take you a specific understanding of the adjustment steps and precautions!
1.check the status of the equipment: ensure that the fog cannon is in the closed state, and disconnect the power supply. This is for safety reasons, to prevent accidents in the regulation process.
2.understand the working principle: understand the working principle of the mist blower, especially the working mechanism of its pressure system. The mist blower rotates the eccentric drive mechanism of the pump through the electric motor, and uses the eccentric effect to make the plunger reciprocate, thus generating a vacuum or pressure to realize the process of water suction and spraying.
3.find the pressure regulator: find the pressure regulator of the mist blower, which is usually located on the control panel of the machine. The pressure regulator usually includes a pressure regulator handwheel and a pressure regulator spring.
4.adjust the pressure level: adjust the pressure by turning the regulator handwheel clockwise or counterclockwise. Clockwise rotation will increase the pressure of the system, while counterclockwise rotation will decrease the pressure. In the adjustment process, adjust gradually, avoid sudden and drastic changes in pressure, so as not to cause damage to the internal mechanism of the mist blower.
5.observe the pressure gauge: in the adjustment process, pay close attention to the reading of the pressure gauge to ensure that the pressure is within the safe and appropriate range.
1. pay attention to safe operation: in the whole adjustment process, to ensure the safety of the operator, avoid direct contact with the power supply or moving mechanical parts. At the same time, make sure to wear appropriate protective equipment, such as gloves and goggles.
2. regular maintenance: Regularly maintain and repair the mist blower to ensure that the regulating mechanism and other components are in good working condition. Regularly check for worn or damaged parts and replace them in time.
3. record the adjustment: record the date of each adjustment, the magnitude of the adjustment and the spray effect after adjustment, which helps un
4.avoid overload: when adjusting the pressure, avoid overloading the system, otherwise it may damage the pump or other key components of the mist blower.
5.keep clean: to ensure that the water inlet and outlet valves are clean, to avoid clogging due to impurities and affect the effect of pressure regulation.
The pressure adjustment of the high-pressure fog cannon is a process that requires careful operation and involves the understanding of the internal mechanism of the mist blower and operating skills. The long-term stability of the mist blower can be ensured through reasonable adjustment.